Page 2 - CULLIGAN WATER

10component of feed water will plug a membrane over time. Use of a softener will reduce the fouling effect on a membrane. One way to detect too much h

Page 3 - Contents

Chapter Heading11To keep the Aqua-Cleer® system operating properly, it is necessary to change the filters and sanitize the system periodically. Typica

Page 4 - About Your

12Preliminary Steps:1. Check for any leaks that may exist from tubing connections or the faucet.2. Check for flow to the drain. If flowing, close tank

Page 5

Chapter Heading13Parts List Item Description1 Manifold Assembly2 5 Micron Sediment Filter10 Micron Sediment Filter25 Micron Sediment Filter3 Carbon Bl

Page 6

Chapter Heading14Important Notice: Read this Performance Data Sheet and compare the capabilities of this system with your actual water treatment need

Page 7

15Total Defense (TD) The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed belo

Page 8

16Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only.Substance Inuent Challenge Concentration mg/LMaximum permiss

Page 9 - Factors Which Affect

17Organic Chemicals Included in Surrogate Testing (Continued):Applies to Total Defense (TD) only.Substance Inuent Challenge Concentration mg/LMaxi

Page 10 - Installation

Chapter HeadingInside Text18RO30 This system has been tested according to NSF/ANSI 58 for the reduction of the substances listed below

Page 11

Chapter Heading19Performance Data Sheet (con’t)RO30 with TD These systems have been tested and certified by NSF International accordin

Page 12 - System (con’t)

THANK YOUAND WELCOME TO YOUR NEW WORLD OF BETTER LIVING WITH CULLIGAN WATER.Notice: Do not use with water that is microbiologically unsafe or of unkno

Page 13 - Parts List

20Total Defense (TD)The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentra

Page 14 - Data Sheet

21Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge Concentration mg/LMaxi

Page 15

22Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Lsimazine 0.120 0.004styrene 0.150 0.

Page 16

23RO30 with AS3These systems have been tested and certified by NSF International according to NSF/ANSI 53 and 58 for the reduction of the substances

Page 17

24AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Page 18

25RO30 with AS3, TDThese systems have been tested and certified by NSF International according to NSF/ANSI 42, 53, and 58 for the reduction of the su

Page 19

26AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Page 20

27Total Defense (TD)The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the sub-stances listed below. The concentr

Page 21

28Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge Concentration mg/LMaxi

Page 22

29Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Lsimazine 0.120 0.004styrene 0.150 0.

Page 23

Table of Contents3About Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Installation .

Page 24

30RO50 This system has been tested according to NSF/ANSI 58 for the reduction of the substances listed below. The concentration of the

Page 25

31Performance Data Sheet (con’t)RO50 with TDThese systems have been tested and certified by NSF International according to NSF/ANSI 42, 53, and 58 for

Page 26

32Performance Data Sheet (con’t)Total Defense (TD)The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substance

Page 27

33Performance Data Sheet (con’t)Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge Concen

Page 28

34Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Lstyrene 0.150 0.0011,1,2,2-tetrachloroethane 0.08

Page 29

35RO50 with AS3These systems have been tested and certied by NSF International according to NSF/ANSI 53 and 58 for the reduction of the substances li

Page 30

36AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Page 31

37RO50 with AS3, TDThese systems have been tested and certied by NSF International according to NSF/ANSI 42, 53, and 58 for the reduction of the subs

Page 32

38AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Page 33

39Total Defense (TD)Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration

Page 34

Chapter Heading4About Your SystemThank you for choosing a Culligan Aqua-Cleer advanced drinking water system. Your new system is designed to bring you

Page 35

40Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge Concentration mg/LMaxi

Page 36

41Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Lsimazine 0.120 0.004styrene 0.150 0.

Page 37

42Performance Data Sheet (con’t)Output (Total Dissolved Solids (TDS) Reduction and Output Production)1 – RO30Tank Size 2 gallon 3 gallon 9 gallonProdu

Page 38

43AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Page 39

Chapter Heading44The Aqua-Cleer Advanced Drinking Water System with CB or GAC cartridge has been tested and certified by NSF International against NSF

Page 40

45California CertificatesCA Certificates - Placeholder

Page 41

46California CertificatesCA Certificates - Placeholder

Page 42

47California CertificatesCA Certificates - Placeholder

Page 43

48California CertificatesCA Certificates - Placeholder

Page 44

49California CertificatesCA Certificates - Placeholder

Page 45 - Certificates

5Sequence of Filtration Type of Filtration SpecificationAdvanced FiltrationTotal DefenseArsenicPerchlorate*Speciality Carbon BlockSpecialty Media 1Spe

Page 46

50California CertificatesCA Certificates - Placeholder

Page 47

51California CertificatesCA Certificates - Placeholder

Page 48

52California CertificatesCA Certificates - Placeholder

Page 49

53California CertificatesCA Certificates - Placeholder

Page 50

54Arsenic Fact SheetArsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must be measured

Page 51

55Arsenic Fact Sheet (con’t)Arsenic (As) is a naturally occurring contaminant found in many ground waters. It generally occurs in two forms (valences

Page 52

56Troubleshooting Guide

Page 53

57Troubleshooting Guide (con’t)

Page 54 - Fact Sheet

58Model Serial No.Date InstalledFor Service Call Culligan at:( ) -Cartridge(s) ChangedDate ServicedSediment FilterActivate

Page 55

59Culligan Lifetime Limited WarrantyCulligan Aqua-Cleer Advanced Drinking Water SystemYou have just purchased one of the finest drinking water systems

Page 56 - Troubleshooting

6• Chloramines have a stronger taste and are more difficult to remove than chlorine. • Mercury is a toxin that can cause kidney damage.• Lead is a

Page 57 - Guide (con’t)

Chapter Heading7To Bottom Of RO CartridgeAqua-Cleer FaucetMonitor SensorMonitorBall ValveTankDrainDrain Line from Air Gap to Drain (3/8” Tubing)Cold W

Page 58 - Service Log

8Important considerations:• Access to the bottom (under sink) of the faucet is required for attachment of product water line.• The faucet can be ins

Page 59 - Warranty

93. Repeat steps 1-3 and install the flushed activated carbon filter cartridge into housing and the RO membrane element. Be sure the drain adapter is